7.11 Air Filter
7.11.1 Air filter element and dust bowl – Cleaning
Preconditions
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Seal
(→ Spare Parts Catalog)
WARNING
Compressed air
Risk of injury!
Do not direct compressed-air jet at persons.
Wear protective goggles / safety mask and ear protectors.
Air filter element – Cleaning
Note: Clean paper filter element dry only.
1. Open air filter and remove filter element
(→ Page 93).
2. Check seal for damage and cleanness, re‐
place if necessary.
3. Clean all mating and sealing surfaces.
Note: Debris particles must not enter the intake
system.
4. Clean dust bowl.
5. Blow out filter element with compressed air
(max. 3 bar) from inside until all dust has
been removed.
6. Fit new filter element if old one is heavily
contaminated or damaged (→ Page 92).