4.7 Plant – Cleaning
Preconditions
Engine is stopped and starting disabled.
Operating voltage is not applied.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Steam jet cleaner
- 1
Cleaner (Hakupur 312)
30390 1
WARNING
Compressed air
Risk of injury!
Do not direct compressed-air jet at persons.
Wear protective goggles / safety mask and ear protectors.
WARNING
Water jet.
Risk of injury and scalding!
Do not direct water jet at persons.
Wear protective clothing, gloves, and goggles / safety mask.
CAUTION
Excessive reaction time of cleaning agents on components.
Damage to component!
Observe manufacturer's instructions.
Wear protective clothing, gloves, and goggles / safety mask.
Note: There is a risk of damaging sensors with compressed air.
Plant – Cleaning
1. Carry out plant cleaning only in areas where an appropriate oil separator is provided (environmental pro‐
tection).
2. Prior to putting the cleaning unit into operation, read the Operating Instructions of the water/steam jet unit
carefully and observe the safety precautions.
3. For external cleaning with high-pressure jet, use a flat-mouth nozzle only.
4. Carry out external cleaning as follows:
a) Remove coarse dirt.
b) Spray on cleaner sparingly and leave it for 1 to 5 minutes.
c) Use the high-pressure jet to remove the loosened dirt.
d) During external cleaning of the plant with water/steam-jet units, the pressure of the high-pressure jet
(cleaning jet) must not exceed 50 bar. A minimum distance between spray nozzle and plant of 1 m
must be observed. The temperature of the cleaning medium must not exceed 80°C.
M015675/05E 2011-10 | Operation | 39