1.4 Crankshaft transport locking device – For transport with
flanged-on generator
Transport
This locking device protects the crankshaft bearings from shocks and vibration damage during unit
transport.
For removal of the transport locking device follow the following instructions:
The transport locking device should remain installed as long as possible during unit installation in
order to avoid damage.
Starting or barring the engine is allowed only with the transport locking device removed. Make sure
that the transport locking device of the generator is removed.
Prior to every unit transport, this transport locking device must be reinstalled according to the in-
structions. The transport locking device of the generator is also to be fitted.
Removing the transport locking device from driving end (KS)
Remove screw (4) on both sides. Remove retainer (2) and washer (3).
Remove guard plate from flywheel housing.
Store the removed parts of the transport locking device carefully for possible reuse!